AskPharmaTutor

Learn | Understand | Practice

Home Serial Dilution Problems with Answers: 15 Worked Calculations

Serial Dilution Problems with Answers: 15 Worked Calculations

Serial dilution problems with answers: 15 worked calculations from single dilutions to CFU/mL and inoculum preparation
Table of Contents

Last reviewed: November 2026 by Dr. Farrukh Mehmood, Ph.D., 16+ years in pharmaceutical QC/QA

Key takeaways

  • 15 serial dilution problems, from a single tube to a USP <61> result and an inoculum for the growth promotion test. Each answer is worked step by step.
  • One tube: dilution = sample ÷ (sample + diluent). 1 mL into 9 mL = 1/10.
  • Several tubes: multiply the step dilutions. Never add them.
  • Back to the sample: CFU/mL or CFU/g = colonies ÷ (volume plated in mL × dilution of that tube).
  • Try each problem first, then open the answer. A one-line answer key is at the end.

Serial dilution is easy to understand and easy to get wrong under pressure: a dilution added instead of multiplied, the wrong plate counted, or a plated volume forgotten. These problems use the numbers a QC microbiology lab actually meets. If you need the method itself first, read the serial dilution guide, which also has a free calculator to check your own work.

The three formulas you need

1. Dilution of one tube
Dilution = sample volume ÷ (sample volume + diluent volume)
0.5 mL into 4.5 mL → 0.5 ÷ 5.0 = 1/10

2. Total (serial) dilution
Total dilution = step 1 × step 2 × step 3 …
1/10 × 1/10 × 1/10 = 1/1000 (10−3)

3. Organisms in the original sample
CFU/mL (or CFU/g) = colonies ÷ (volume plated in mL × dilution)
42 colonies, 0.1 mL of 10−5 → 42 ÷ (0.1 × 10−5) = 4.2 × 107

The dilution is the fraction of the original sample in the tube (1/10, or 10−1). The dilution factor is its reciprocal (10). Dividing by the dilution and multiplying by the dilution factor give the same answer.

Level 1: single dilutions

Problem 1

You add 0.5 mL of a culture to 4.5 mL of sterile diluent. What is the dilution, and what is the dilution factor?

Show answer

Total volume = 0.5 + 4.5 = 5.0 mL.
Dilution = 0.5 ÷ 5.0 = 1/10 (10−1). Dilution factor = 10.

Smaller volumes give the same tenfold step as 1 mL into 9 mL, as long as the ratio is the same.

Problem 2

You add 1 mL of sample to 4 mL of diluent. What is the dilution?

Show answer

Total volume = 1 + 4 = 5 mL. Dilution = 1 ÷ 5 = 1/5 (dilution factor 5).

The common mistake is 1/4: the diluent volume alone is not the total volume.

Problem 3

A disinfectant concentrate must be used at 1 in 20. How much concentrate and how much purified water do you need for 500 mL of in-use solution?

Show answer

Concentrate = 500 ÷ 20 = 25 mL. Water = 500 − 25 = 475 mL.

“1 in 20” means 1 part in 20 parts total, the same convention as microbiology dilutions. Check the label: some manufacturers write “1:20” to mean 1 part plus 20 parts.

Level 2: serial (total) dilutions

Problem 4

You make three tenfold dilutions in a row: 1 mL into 9 mL, three times. What is the dilution of the third tube?

Show answer

1/10 × 1/10 × 1/10 = 1/1000 (10−3).

Not 3/10 and not 1/30: step dilutions multiply.

Problem 5

Step 1: 1 mL into 99 mL. Step 2: 1 mL of that into 9 mL. Step 3: 0.1 mL of that into 9.9 mL. What is the final dilution?

Show answer

Step 1 = 1/100. Step 2 = 1/10. Step 3 = 0.1 ÷ 10.0 = 1/100.
Total = 1/100 × 1/10 × 1/100 = 1/100,000 (10−5).

Steps do not have to be the same size. Work out each one, then multiply.

Problem 6

Step 1: 1 mL into 4 mL. Step 2: 0.5 mL of that into 4.5 mL. What is the total dilution?

Show answer

Step 1 = 1/5. Step 2 = 0.5 ÷ 5.0 = 1/10.
Total = 1/5 × 1/10 = 1/50 (dilution factor 50).

Problem 7

For an MIC test you make a twofold series: 1 mL of an antibiotic solution at 128 µg/mL into 1 mL of broth, then 1 mL of that into the next 1 mL of broth, for six tubes. What is the concentration in each tube?

Show answer

Each step is 1 ÷ (1 + 1) = 1/2, so the concentration halves each time:

64, 32, 16, 8, 4 and 2 µg/mL (tube 6 = 128 × (1/2)6 = 2 µg/mL).

The concentrations above are before inoculum is added. If the method adds an equal volume of inoculum to each tube, every final concentration halves again.

Level 3: from colonies back to CFU/mL or CFU/g

Problem 8

You pour-plate 1 mL of the 10−4 dilution and count 156 colonies. What was the concentration in the original suspension?

Show answer

CFU/mL = 156 ÷ (1 × 10−4) = 1.56 × 106 CFU/mL (report as 1.6 × 106).

Problem 9

You spread 0.1 mL of the 10−5 dilution and count 42 colonies. What was the original concentration?

Show answer

CFU/mL = 42 ÷ (0.1 × 10−5) = 42 ÷ 10−6 = 4.2 × 107 CFU/mL.

Forgetting the 0.1 mL is the most common spread-plate error: it gives an answer ten times too low.

Problem 10

Duplicate pour plates (1 mL each) give these counts. Which plates do you use, and what is the result?

DilutionPlate APlate B
10−2TNTCTNTC
10−3212198
10−42319
Show answer

Use the 10−3 plates. They are in the countable range, and they have the highest count below 250 (the USP <61> rule for TAMC pour plates).

Mean = (212 + 198) ÷ 2 = 205. CFU/mL = 205 ÷ 10−3 = 2.05 × 105 CFU/mL (report as 2.1 × 105).

Check: the 10−4 plates give a mean of 21, which is 2.1 × 105. The two dilutions agree, which is a good sign that the series was made correctly.

Problem 11

TAMC of a tablet: 10 g of powdered tablets in 90 mL of diluent (10−1). Duplicate pour plates of 1 mL give 37 and 45 colonies. The limit for this non-aqueous oral product is 103 CFU/g. Does the batch comply?

Show answer

Mean = (37 + 45) ÷ 2 = 41. CFU/g = 41 ÷ (1 × 10−1) = 410 CFU/g.

Under USP <1111>, a limit of 103 allows a maximum count of 2,000 CFU/g. The batch complies.

All limits by dosage form: TAMC and TYMC limits (USP <1111>).

Problem 12

TYMC of a syrup: 10 mL in 90 mL of diluent (10−1). Duplicate pour plates of 1 mL on Sabouraud Dextrose Agar give 8 and 6 colonies. The TYMC limit for aqueous oral products is 101 CFU/mL. Does the batch comply?

Show answer

Mean = (8 + 6) ÷ 2 = 7. CFU/mL = 7 ÷ 10−1 = 70 CFU/mL.

A limit of 101 allows a maximum of 20 CFU/mL. The batch does not comply: this is an out-of-specification result, and an OOS investigation starts with the lab (media, controls, technique) before any retest.

A small plate count can still fail: the 10−1 dilution multiplies every colony by 10.

Problem 13

Both 1 mL pour plates of the 10−1 dilution of a capsule sample show no colonies. How do you report the TAMC?

Show answer

Do not report 0. The lowest count the method can detect is 1 colony on a 10−1 plate, which is 10 CFU/g. Report less than 10 CFU/g (<10 CFU/g): less than 1 multiplied by the dilution factor of the lowest dilution tested.

This is the usual convention, but USP <61> does not set the wording, so follow the reporting rule in your SOP.

Level 4: working backwards and planning a series

Problem 14

A growth promotion test needs an inoculum of not more than 100 CFU. Your stock suspension has 2.4 × 108 CFU/mL, and you will inoculate 0.1 mL. Which tenfold dilution do you use?

Show answer

At 10−5: 2.4 × 108 × 10−5 = 2,400 CFU/mL, so 0.1 mL = 240 CFU. Too many.

At 10−6: 240 CFU/mL, so 0.1 mL = 24 CFU. This meets “not more than 100 CFU”. (0.2 mL of the same tube would give 48 CFU, if you want a count nearer the middle of the range.)

Always confirm the actual inoculum by plating it at the same time. The stock count is only an estimate. See the growth promotion test guide for the acceptance criteria.

Problem 15

You expect a culture to contain about 107 CFU/mL. You will pour-plate 1 mL and want 25–250 colonies on the plate. Which dilutions do you plate?

Show answer

At 10−5, 1 mL holds about 107 × 10−5 = 100 CFU, which is in range. At 10−4 you expect about 1,000 (too many). At 10−6 you expect about 10 (too few, but useful if the estimate is high).

Plate 10−4, 10−5 and 10−6, in duplicate. Bracketing the expected dilution protects you if the estimate is off by tenfold either way.

Answer key

ProblemAnswer
11/10 (dilution factor 10)
21/5
325 mL concentrate + 475 mL water
410−3
510−5
61/50
764, 32, 16, 8, 4, 2 µg/mL
81.56 × 106 CFU/mL
94.2 × 107 CFU/mL
1010−3 plates; 2.05 × 105 CFU/mL
11410 CFU/g; complies (max 2,000)
1270 CFU/mL; does not comply (max 20)
13<10 CFU/g
1410−6; 0.1 mL = 24 CFU
15Plate 10−4, 10−5, 10−6

Five mistakes these problems are built around

  • Using the diluent volume as the total. 1 mL into 4 mL is 1/5, not 1/4.
  • Adding step dilutions. Three tenfold steps are 10−3, not 3/10.
  • Forgetting the plated volume. A 0.1 mL spread plate needs the extra factor of 10.
  • Counting the wrong plate. Use the plates in the countable range: for USP <61> pour plates, the highest count below 250 (TAMC) or 50 (TYMC).
  • Reading 103 as a maximum of 1,000. Under USP <1111>, 103 allows up to 2,000.

Test yourself on the wider topic with the free QC microbiology quiz or the pharmaceutical calculations quiz.

Frequently asked questions

How do you calculate a serial dilution?

Work out the dilution of each tube as sample volume ÷ (sample + diluent volume), then multiply the step dilutions together. Three steps of 1 mL into 9 mL give 1/10 × 1/10 × 1/10 = 1/1000.

How do you calculate CFU/mL from a serial dilution?

Divide the colony count by the volume plated (in mL) and by the dilution of the tube you plated. 42 colonies from 0.1 mL of the 10−5 tube = 42 ÷ (0.1 × 10−5) = 4.2 × 107 CFU/mL.

What do you report if no colonies grow?

By convention, report less than 1 multiplied by the dilution factor of the lowest dilution tested. With 1 mL of a 10−1 dilution plated, that is <10 CFU/g or CFU/mL. Follow the exact wording in your SOP.

Related guides

References

  • USP General Chapter <61> Microbiological Examination of Nonsterile Products: Microbial Enumeration Tests.
  • USP General Chapter <1111> Microbiological Examination of Nonsterile Products: Acceptance Criteria for Pharmaceutical Preparations and Substances for Pharmaceutical Use.
  • European Pharmacopoeia 2.6.12 Microbial examination of non-sterile products: microbial enumeration tests.
Table of Contents
Free Pharma Lab Toolkit
Assay, RSD, molarity and sample-size calculators for QC analysts.
Picture of Dr. Farrukh Mehmood, Ph.D.
Dr. Farrukh Mehmood, Ph.D.
Dr. Farrukh Mehmood is a pharmaceutical quality professional with more than 16 years in QC and QA. He is Senior Manager, Quality Operations at a multi-site pharmaceutical manufacturer in Pakistan and a PNAC-accredited ISO/IEC 17025 Lead Assessor and Technical Assessor. He holds a Pharm-D, an M.Phil and a PhD in Pharmaceutics, supervises research theses at Riphah Institute of Pharmaceutical Sciences, and founded AskPharmaTutor to share practical, regulation-based guidance with pharmacists and QC/QA teams.